Picc Excellence logo

PICC Excellence, Inc

Picc Excellence Twitter Icon Picc Excellence Facebook Icon
Shopping Cart Image
login/create account

Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review

Content:
Nancy L. Moureau and Julie Flynn, Disinfection of Needleless Connector Hubs: Clinical Evidence Systematic Review, 2015, Nursing Research and Practice, Article ID 796762, in press. Background. Needleless connectors (NC) are used on virtually all intravascular devices, providing an easy access point for infusion connection. Colonization of NC is considered the cause of 50% of postinsertion catheter-related infections. Breaks in aseptic technique, from failure to disinfect, result in contamination and subsequent biofilm formation within NC and catheters increasing the potential for infection of central and peripheral catheters. Methods. This systematic review evaluated 140 studies and 34 abstracts on NC disinfection practices, the impact of hub contamination on infection, and measures of education and compliance. Results. The greatest risk for contamination of the catheter after insertion is the NC with 33-45% contaminated, and compliance with disinfection as low as 10%. The optimal technique or disinfection time has not been identified, although scrubbing with 70% alcohol for 5-60 seconds is recommended. Studies have reported statistically significant results in infection reduction when passive alcohol disinfection caps are used (48-86% reduction). Clinical Implications. It is critical for healthcare facilities and clinicians to take responsibility for compliance with basic principles of asepsis compliance, to involve frontline staff in strategies, to facilitate education that promotes understanding of the consequences of failure, and to comply with the standard of care for hub disinfection. Link to pdf https://www.researchgate.net/publication/277897307_Disinfection_of_Needleless_Connector_Hubs_Clinical_Evidence_Systematic_Review

Return to Resource Center

| Education | Resource Center | Consulting | Contact Us | About Us | Site Map

PICC Excellence Inc. an educational service for clinicians



Picc Excellence Twitter Icon Picc Excellence Facebook Icon

401 E. Howell St. Hartwell, GA 30643

info@piccexcellence.com

(706) 377 3360

PICC Certification ™ and CPUI ™ are trademarks. Used under license. © 2019 PICC Excellence, Inc. All Rights Reserved.

Provider approved by the California Board of Registered Nursing. Provider # CEP15304, and Florida Board of Nursing Provider # 50-1594. And the Canadian Association of Medical Radiation Technologists (CAMRT)